Fault Description | System Behaviour |
---|---|
226 | Service tool has been connected in the blocking error history menu |
FD 231 | The power has been interrupted during a lockout |
C7 214 | Fan does not run during the start up phase – fan harness connector needs checking |
C6 215 | Fan speed too high – check the fan harness and connector |
C7 216 | Fan speed too low – check the fan harness and connector |
C7 217 | Fan has stopped during appliance operation |
C1 264 | Fan stopped during operation |
C4 273 | Continuous fan operation for the last 24 hours – appliance temporarily blocked |
E2 222 | Flow temperature sensor shorted |
E2 233 | Flow temperature sensor disconnected |
E9 276 | Primary flow temperature exceeded 95°c |
E2 350 | Flow temperature sensor shorted |
E2 351 | Flow temperature sensor disconnected |
FA 306 | Ionisation detected after the gas valve closed |
EA 227 | No ionisation detected after ignition |
F7 228 | Isioniation current detected before burner start |
EA 229 | Loss of ionisation signal during operation |
EA 261 | Heat control module (HCM) potentially defective – reset the appliance |
9U 233 | Control box or heat control module (HCM) is defective or loose, the HCM needs to be checked |
C4 237 | Control box or heat control module (HCM) is defective |
F0 238 | Gas valve or control box error – gas valve coils need checking |
F0 239 | Control box or the heat control module (HCM) is defective – the control box connections need checking |
F0 242 | Control box or the heat control module (HCM) is defective – the HCM and control box connections need to be checked |
B7 257 | Control box or the heat control module HCM) is defective- the HCM and control box connections need to be checked |
F0 258 | Control box or the heat control module (HCM) is defective – HCM or control box connections need to be checked |
EH 258 | Control box or the heat control module (HCM) is defective – HCM or control box connections need to be checked |
F1 259 | Control box or the heat control module (HCM) is defective – HCM or control box connections need to be checked |
F0 262 | Control box or the heat control module (HCM) is defective – HCM or control box connections need to be checked |
F1 263 | Control box or the heat control module (HCM) is defective – HCM or control box connections need to be checked |
F0 272 | Control box or the heat control module (HCM) is defective – control box and connections need checking or HCM might not be inserted properly and need replacing |
F0 280 | Control box or the heat control module (HCM) is defective – control box and connections need checking or HCM might not be inserted properly and need replacing |
F0 290 | Control box is defective – HCM needs checking as it might not be inserted properly or need replacing |
328 | Internal error with the mains voltage – frequency may be inconsistent |
235 | Incompatible heat control module (HCM) software versions – control box needs latest software |
356 | Low mains voltage – the voltage may be interrupted or inconsistent and needs checking |
360 | Heat control module (HCM) invalid – the inserted HCM does not correspond with the control box |
A8 362 | Low mains voltage – the voltage may be interrupted, inconsistent or heat control module (HCM) invalid |
CC 800 | Outdoor sensor defect available when accessory outdoor sensor is connected |
A1 281 | Pump stock or running dry |
E9 224 | Flue or high limit thermostat activated |
D4 341 | Primary flow temperature rising too fast |