| Fault Description | System Behaviour |
|---|---|
| A1 | Water is leaking or the pump needs replacing or freeing due to the pump running dry. |
| A7 | The hot water negative thermistor coefficient (NTC) sensor is defective – the hot water sensor or connecting leads need checking. |
| A8 | Break communication to FX sensor controls electrical connections need checking. |
| B1 | Code plug not detected . |
| C6 | Fan speed too low – the fan lead and connector need checking and may need replacing. |
| E2 | Central heating (CH) water flow negative thermistor coefficient (NTC) sensor defective check CH flow NTC sensor and connection leads. |
| E9 | Safety temperature limiter in central heating (CH) flow has tripped the system pressure or safety temperature limiter needs checking |
| EA | Flame not detected due to a gas issue – the gas supply, power supply or igniter, electrode and lead need checking – contact a Gas Safe installer. |
| F0 | Internal error – electrical connector contacts or programmer interface module – check ignition leads are not loose. |
| F7 | Flame detected even though the appliance is switched off – check the electrode assembly is dry and the pcb and flue are clear. |
| FA | Flame detected after gas shut off – the gas valve needs checking – hire a Gas Safe installer. |
| FD | Reset button pressed by mistake – press reset button again. |